EMF Shielding Paint & Shielding Fabric
for large-scale shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges non-slip, dimensionally stable glass fibre fabric with fine stainless steel filaments woven in reinforcement qualities G-ES-Special is a glass fibre fabric interwoven with metal. It is excellently suited for shielding from high-frequency electromagnetic waves in construction and also shields from low-frequency electric alternating fields. Processing glass fibre fabric G-ES is an identical procedure to that of conventional reinforcement fabric. Particularly suited for loose installation in visible areas or beneath thin plaster or filling layers. Developed for interior areas. Can also be used in outdoor areas.
for large-scale shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges finely woven, corrosion-proof wire mesh made of special steel breathable, tear-resistant, and flexible fabric for use in dry construction Adamantan 003 is a very finely woven, corrosion-proof special steel mesh for shielding from high-frequency electromagnetic waves and low-frequency electric alternating fields. Adamantan 003 is used for roofs, walls, and ceilings, primarily in dry construction. Special uses, e. g. as a fly screen or possible partitions. Due to the high shielding attenuation (~50 dB), the fabric also meets the highest demands. Through the fine and flexible structure of the fabric, even complicated wall areas such as wall penetrations, corners, window reveals, and similar areas can be effectively covered and perfectly integrated into the shielding area. Through the very fine, nearly textile feel and the possibility of sewing the material, it is also conceivable to create a bed canopy from Adamantan 003.
for large-scale shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges finely woven, corrosion-proof wire mesh made of special steel breathable, tear-resistant, very durable and flexible Adamantan 10 is a finely woven, corrosion-proof special steel mesh for shielding from high-frequency electromagnetic waves and low-frequency electric alternating fields. The fabric's surface activation occurs especially for the use as a shielding fabric (deoiled and degreased). This increases the contactability and leads to low transition resistance. For comparable, mostly cheaper stainless steel mesh, the oil and grease layer forms an insulating film, making the incorporation of the fabric into the function equipotential bonding more difficult. One of our bestselling fabrics, Adamantan 10 comes into use in roof and outer wall areas, in wood stand building construction as well as full heating insulation. The fabric can be used beneath plaster and in dry construction. Due to the missing tensile strength and tear-resistance, an additional reinforcement fabric should be used for the application beneath plaster outdoors.
for large-scale shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges Non-woven for use in dry construction full-surface copper-plated high shielding efficiency > 70 dB open to vapour diffusion, balanced tensile strength Saphir Extra is a highly shielding, particularly light, corrosion-resistant, breathable and tear-resistant copper fleece for shielding high-frequency electromagnetic waves and low-frequency alternating electric fields. Saphir Extra is used in roofs, walls, ceilings floors lining under. Special applications, e.g. as underlayment wallpaper, for processing in simple cell phone cases or for RFID shielding are also possible. Due to the high shielding effectiveness (~ 70 dB), the non-woven meets the highest requirements.
for large-area shielding of low-frequency alternating electric fields and dissipation of static charges fibre fleece, open to vapour diffusion easy to contact, for loose and fixed installation Rubens Light is an electrically conductive fibre fleece based on graphite, vapour diffusible, flexible and conditionally tear-resistant The Rubens-Light shielding fleece is easy to install and is preferably used in living and working spaces. It can be laid loosely or glued under carpets, behind or between gypsum plasterboards, wooden boarding, or can also be used as a solid under-wallpaper with wallpaper paste for heavy wallpapers. For the shielding of low-frequency alternating electric fields to function, it is absolutely necessary to „earth" the shielding surface in the equipotential bonding. Various earthing accessories are available for this purpose.
for large-area shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges best price-performance ratio with the optimised high-frequency shielding paint HiFreq-Standard-Liquid with coarser pigmentation, slightly less tensile adhesion and, compared to the Biologa Danell shielding paint HiFreq- Premium-Liquid, a shielding effect in the midfield very good spreadability due to thinner quality very low-emission shielding paint for indoor use metal-free, physically extremely stable, durable and non-oxidising, frost-resistant high water resistance, eleastically soft Highly electrically conductive wall coating based on synthetic resin. The paint is vapour diffusible and contains no solvents, plasticisers, low-volatile organic compounds, formaldehyde or ammonia. HiFreq Standard Liquid adheres well to most non-greasy and load-bearing surfaces indoors and can be easily painted or wallpapered over. Painting over existing wallpaper is advisable if the shielding surface is to be removed without leaving any residue in the foreseeable future. The shielding paint HiFreq Standard Liquid can be overpainted very well with e.g. plastic-bonded emulsion paints, but also with various other topcoats. Simply carry out a test with your chosen top coat.
for large-area shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges very good price-performance ratio with slightly less shielding effectiveness and adhesive strength compared to our HiFreq Premium Fluid Shielding Paint powder form for easy stirring with water very long storage life of approx. 5 years very low-emission shielding paint for indoor use metal-free, physically extremely stable, durable and non-oxidising, frost-resistant high water resistance, eleastically soft Highly electrically conductive wall coating based on synthetic resin. The paint is vapour diffusible and contains no solvents, plasticisers, low-volatile organic compounds, formaldehyde or ammonia. HiFreq Standard Powder adheres well to most non-greasy and load-bearing surfaces indoors and can be easily painted or wallpapered over. Painting over existing wallpaper is advisable if the shielding surface is to be removed without leaving any residue in the foreseeable future. Possible top coats: plastic-bonded dispersion paints Dispersion silicate paints (KEIM - Ecosil, Biosil, Optil) clay paints: Volvox clay paint lime paints: Haga lime paint Top coats only with prior test: mineral coatings
for large-area shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges best shielding effectiveness with the improved high frequency shielding paint HiFreq-Premium-Liquid. very good tensile adhesion in comparison to the Biologa Danell shielding paint HiFreq-Standard-Powder + -Liquid, can therefore also be used under tiles, for example very low-emission shielding paint for indoor and outdoor use metal-free, physically extremely stable, durable and non-oxidising, frost-resistant high water resistance, eleastically soft highly electrically conductive wall coating based on synthetic resin. The paint is vapour diffusible and contains no solvents, plasticisers, low-volatile organic compounds, formaldehyde or ammonia. HiFreq Premium Liquid adheres well to most non-greasy and load-bearing surfaces indoors and outdoors and can be easily painted or wallpapered over. Can be used under organic plasters after priming. Painting over existing wallpaper is advisable if the shielding surface is to be removed without leaving any residue in the foreseeable future. Possible top coats: plastic-bonded dispersion paints Dispersion silicate paints (KEIM - Ecosil, Biosil, Optil) clay paints: Volvox clay paint lime paints: Haga lime paint Top coats only with prior test: mineral coatings (plasters) such as clay, lime or pure silicate
for large-area shielding of high-frequency electromagnetic waves, low-frequency alternating electric fields and dissipation of static charges best shielding effectiveness with the improved high frequency shielding paint HiFreq-Premium-Liquid. very good tensile adhesion in comparison to the Biologa Danell shielding paint HiFreq-Standard-Powder + -Liquid, can therefore also be used under tiles, for example very low-emission shielding paint for indoor and outdoor use metal-free, physically extremely stable, durable and non-oxidising, frost-resistant high water resistance, eleastically soft highly electrically conductive wall coating based on synthetic resin. The paint is vapour diffusible and contains no solvents, plasticisers, low-volatile organic compounds, formaldehyde or ammonia. HiFreq Premium Liquid adheres well to most non-greasy and load-bearing surfaces indoors and outdoors and can be easily painted or wallpapered over. Can be used under organic plasters after priming. Painting over existing wallpaper is advisable if the shielding surface is to be removed without leaving any residue in the foreseeable future. Possible top coats: plastic-bonded dispersion paints Dispersion silicate paints (KEIM - Ecosil, Biosil, Optil) clay paints: Volvox clay paint lime paints: Haga lime paint Top coats only with prior test: mineral coatings (plasters) such as clay, lime or pure silicate
Colour quirl for drilling machines with toothed rim drill chuck, single- and double-barrel drill chucks (quick-action chuck) the hexagonal shank prevents the paint mixer from spinning in the drill chuck and the mixer from slipping through Due to the ergonomic design of the mixer, shielding paints can be stirred reliably in the shortest possible time in the supplied container to form a homogeneous paint ready for painting Fits all HiFreq containers, also the canister of HiFreq-standard-liquid 5 litres
for grounding at the equipotential bonding of construction fabrics, shielding fleeces, and shielding paint conductive adhesive surfaces with adhesive cover for secure shielding of electric alternating fields Electrically conductive ground strap for connection to equipotential bonding. The band is used for "grounding" several sheets of shielding fleece (Rubens Light), shielding fabrics (Adamantan 003), or of surfaces with painted shielding colors (NF45, HF65). Both the fleece layer as well as the adhesive layer of the self-adhesive ground strap are constructed so as to be electrically conductive. The band can thus be attached on as well as beneath shielding paint, for example. Biologa recommends initially gluing the band in the socket area and then coating it with shielding paint. This provides an optimal hold of the band on the wall. IMPORTANT! Fixing the ground strap AEB 3.0 does not need to be carried out by a qualified electrician. You can do this yourself beforehand. All electric work (connection of the grounding plate to the equipotential bonding, work with electric devices and systems) must be carried out and inspected by a qualified electrician or under their guidance and supervision! Only use the ground strap in dry interior rooms at a normal temperature. No open outdoor use!
for incorporating existing shield areas into equipotential bonding corrosion-resistant stainless steel components The grounding plate EGP is a small component made of stainless steel to incorporate existing shielding areas into the (functional) equipotential bonding ("grounding"). The small version of the grounding plate can, for example, enable the discrete integration of surfaces painted with shielding paint beneath the skirting board in the equipotential bonding. Grounding components are thereby no longer visible in this area. IMPORTANT! The necessary installation must be carried out by a qualified electrician. A fault-current circuit breaker (FI or RCD ≤ 30mA) must be present in the electric circuit. Your electrician will install this standard device for you, if not already present. All electric work (work on electric devices and systems) must be carried out and examined by a qualified electrician or under their guidance and supervision!
for incorporating existing shield areas into equipotential bonding corrosion-proof stainless steel components The stainless steel ground strap is a component made of stainless steel to incorporate existing shielding areas with construction fabrics, such as Adamantan 10 or G-ES special, into the equipotential bonding "grounding". IMPORTANT! The necessary installation must be carried out by a qualified electrician. A fault-current circuit breaker (FI or RCD ≤ 30mA) must be present in the electric circuit. Your electrician will install this standard device for you, if not already present. All electric work (work on electric devices and systems) must be carried out and examined by a qualified electrician or under their guidance and supervision!
for connection to stainless steel earthing tape EEB corrosion-resistant stainless steel component for stranded and fine-stranded round conductors, e.g. according to DIN EN 60228 Kl. 2 and 5 for round-pressed stranded sector conductors ideal for aggressive environmental conditions, acid and rust resistant The tubular cable lug RKS is a small component made of stainless steel for connection on the stainless steel earthing strap EEB. Both components are made of stainless steel and thus prevent galvanic corrosion. IMPORTANT! The necessary installation must be carried out by a qualified electrician. A residual current circuit breaker (FI or RCD ≤ 30 mA) must be present in the circuit. Your electrician will install this standard device for you if it is not available. All electrical work (work on electrical equipment and installations) must be carried out and inspected by a qualified electrician or under their direction and supervision! You can also find more information on this at: www.funktionspotentialausgleich.de
for connection to stainless steel earthing tape EEB corrosion-resistant stainless steel component for stranded and fine-stranded round conductors, e.g. according to DIN EN 60228 Kl. 2 and 5 for round-pressed stranded sector conductors ideal for aggressive environmental conditions, acid and rust resistant The tubular cable lug RKS is a small component made of stainless steel for connection on the stainless steel earthing strap EEB. Both components are made of stainless steel and thus prevent galvanic corrosion. IMPORTANT! The necessary installation must be carried out by a qualified electrician. A residual current circuit breaker (FI or RCD ≤ 30 mA) must be present in the circuit. Your electrician will install this standard device for you if it is not available. All electrical work (work on electrical equipment and installations) must be carried out and inspected by a qualified electrician or under their direction and supervision! You can also find more information on this at: www.funktionspotentialausgleich.de
for connection to stainless steel earthing tape EEB corrosion-resistant stainless steel component for stranded and fine-stranded round conductors, e.g. according to DIN EN 60228 Kl. 2 and 5 for round-pressed stranded sector conductors ideal for aggressive environmental conditions, acid and rust resistant The tubular cable lug RKS is a small component made of stainless steel for connection on the stainless steel earthing strap EEB. Both components are made of stainless steel and thus prevent galvanic corrosion. IMPORTANT! The necessary installation must be carried out by a qualified electrician. A residual current circuit breaker (FI or RCD ≤ 30 mA) must be present in the circuit. Your electrician will install this standard device for you if it is not available. All electrical work (work on electrical equipment and installations) must be carried out and inspected by a qualified electrician or under their direction and supervision! You can also find more information on this at: www.funktionspotentialausgleich.de
grounding plug for earthed sockets (Schuko) grounding system for use with versatile different grounding cables connection of up to four grounding cables Personal protection in accordance with DIN VDE 0100 For earthing with earthing cable ESR-DK, ESR-ST, ESR-USB + Accessories IMPORTANT NOTICE! Safety-related protective conductor connection. Connection and disconnection only by qualified service personnel! The corresponding circuit may only be operated with a residual current circuit breaker smaller than 30mA (FI or RCD).
EMF Shielding Paint & Shielding Fabric
Application:
Shielding paints and fabrics are a highly effective solution for reducing high-frequency electromagnetic radiation in residential, commercial and public buildings. Shielding paints are applied in the same way as conventional wall paints, creating an invisible, conductive shielding layer on walls, ceilings and façades. Shielding fabrics are integrated directly into the building structure, for instance beneath plaster, within drywall systems, or under flooring. Both solutions can be seamlessly incorporated into modern building concepts, whether for new construction or renovation projects. When installed by a professional, they offer optimum performance and contribute to reducing both high-frequency radiation and low-frequency electric fields.
Benefits:
Create a healthier and more comfortable living environment with our proven shielding solutions. Shielding paints offer excellent attenuation performance and can be installed in a way that is virtually invisible. Shielding fabrics provide outstanding conductivity and highly efficient, large-area shielding using minimal material. Both products are durable and reliable, and are designed for long-term use. Together, they form the basis of a professional shielding concept that reduces electromagnetic exposure, supports healthy indoor spaces and enhances quality of life. They are ideal for bedrooms, living areas, offices, schools, healthcare facilities, and other sensitive environments.