Shielded Modular Power System
shielded 3-way socket module without switch for shielding low-frequency alternating electric fields can be used with or without additional switch MSDS-SA Modular system:Completely modular design, for connection in rows. Various system strips for selectable number of slots, with connection cables and interlinking cables in several lengths (from 0.5 m up to 5 m). Flexible and adaptable, without cable clutter. Sockets can be optionally switched off / not switched off by means of a 2-pole switch. Up to 10 system strips may be plugged in one after the other without endangering the short-circuit protection. Applications for example for office workstations, hi-fi systems, TV combinations... The alternating electric field is minimised to 1-2 volts/metre (V/m). The recommended guideline value of building biology is max. 10 V/m. Please note when installing: Let the mains cable run at least 80 mm straight at the plug and socket. Use of socket modules with 2-pole switch: By using switchable modules, several units can be connected together and conveniently disconnected from the mains together by using of a switch. If there is a need for continuous power for units with programmed data or necessary accessibility, you can use the modules with combined disconnectable and non-disconnectable inserts.
shielded 3-way socket module with switch for shielding low-frequency alternating electric fields two-pole disconnection of the socket inserts, the following modules are not disconnected Modular system:Completely modular design, for connection in rows. Various system strips for selectable number of slots, with connection cables and interlinking cables in several lengths (from 0.5 m up to 5 m). Flexible and adaptable, without cable clutter. Sockets can be optionally switched off / not switched off by means of a 2-pole switch. Up to 10 system strips may be plugged in one after the other without endangering the short-circuit protection. Applications for example for office workstations, hi-fi systems, TV combinations... The alternating electric field is minimised to 1-2 volts/metre (V/m). The recommended guideline value of building biology is max. 10 V/m. Please note when installing: Let the mains cable run at least 80 mm straight at the plug and socket. Use of socket modules with 2-pole switch: By using switchable modules, several units can be connected together and conveniently disconnected from the mains together by using of a switch. If there is a need for continuous power for units with programmed data or necessary accessibility, you can use the modules with combined disconnectable and non-disconnectable inserts. Note: DIN VDE 0100 Part 420 Para. 4.1 (fire hazard in electrical installations) must be particularly observed during use. If the total resistance of the individual plug-in connections exceeds the impedance required for short-circuit protection, it will no longer trip (VDE 0100-410:2007-06 requires short disconnection times of 0.4 s for the TN system). In such cases, the temperature of the line can rise until a fire originates. Therefore, the following applies (for all modules, whether shielded or unshielded): plug in up to a maximum of ten modules in a row do not operate covered
shielded 5-way socket module without switch for shielding low-frequency alternating electric fields can be used with or without additional switch MSDS-SA Modular system:Completely modular design, for connection in rows. Various system strips for selectable number of slots, with connection cables and interlinking cables in several lengths (from 0.5 m up to 5 m). Flexible and adaptable, without cable clutter. Sockets can be optionally switched off / not switched off by means of a 2-pole switch. Up to 10 system strips may be plugged in one after the other without endangering the short-circuit protection. Applications for example for office workstations, hi-fi systems, TV combinations... The alternating electric field is minimised to 1-2 volts/metre (V/m). The recommended guideline value of building biology is max. 10 V/m. Please note when installing: Let the mains cable run at least 80 mm straight at the plug and socket. Use of socket modules with 2-pole switch: By using switchable modules, several units can be connected together and conveniently disconnected from the mains together by using of a switch. If there is a need for continuous power for units with programmed data or necessary accessibility, you can use the modules with combined disconnectable and non-disconnectable inserts.
mounting accessories for modular socket system MSDS for connecting several modules directly to each other, using double couplers and double cover and connecting strips simple cover strips and end caps to prevent dust ingress in exposed plug or socket single-screw fastening for flat under-table or wall mounting locking clip as replacement or exchange
shielded system full protection module without switch for shielding low-frequency alternating electric fields for overvoltage protection and mains filtering at the beginning of a system module row. Mostly after the MSDS-SA switch full electrical protection „PRO-TECTOR", mains and HF filter Modular system:Completely modular design, for connection in rows. Various system strips for selectable number of slots, with connection cables and interlinking cables in several lengths (from 0.5 m up to 5 m). Flexible and adaptable, without cable clutter. Sockets can be optionally switched off / not switched off by means of a 2-pole switch. Up to 10 system strips may be plugged in one after the other without endangering the short-circuit protection. Applications for example for office workstations, hi-fi systems, TV combinations ... The alternating electric field is minimised to 1-2 volts/metre (V/m). The recommended guideline value of building biology is max. 10 V/m. Please note when installing: Let the mains cable run at least 80 mm straight at the plug and socket. Use of socket modules with 2-pole switch: By using switchable modules, several units can be connected together and conveniently disconnected from the mains together by using of a switch.
mounting accessories for modular socket system MSDS for connecting several modules directly to each other, using double couplers and double cover and connecting strips simple cover strips and end caps to prevent dust ingress in exposed plug or socket single-screw fastening for flat under-table or wall mounting locking clip as replacement or exchange
shielded switch module for shielding low-frequency alternating electric fields two-pole disconnection of all following modules Modular system:Completely modular design, for connection in rows. Various system strips for selectable number of slots, with connection cables and interlinking cables in several lengths (from 0.5 m up to 5 m). Flexible and adaptable, without cable clutter. Sockets can be optionally switched off / not switched off by means of a 2-pole switch. Up to 10 system strips may be plugged in one after the other without endangering the short-circuit protection. Applications for example for office workstations, hi-fi systems, TV combinations ... The alternating electric field is minimised to 1-2 volts/metre (V/m). The recommended guideline value of building biology is max. 10 V/m. Please note when installing: Let the mains cable run at least 80 mm straight at the plug and socket. Use of socket modules with 2-pole switch: By using switchable modules, several units can be connected together and conveniently disconnected from the mains together by using of a switch. If there is a need for continuous power for units with programmed data or necessary accessibility, you can use the modules with combined disconnectable and non-disconnectable inserts.
very flexible and bendable mains connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for connection of the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable mains connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for connection of the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable mains connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for connection of the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable mains connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for connection of the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable mains connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for connection of the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable interlinking connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for linking the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable interlinking connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for linking the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable interlinking connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for linking the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
very flexible and bendable interlinking connection cable for modular socket system connection of socket, switch and protection modules plastic-coated aluminium strip, copper wire min. 1.00 mm², fine-stranded shield (alternating electric field, 50 Hz mains voltage) reduction of the alternating magnetic field through twisting protection class 1 - with PE protective conductor Shielded flexible cable for linking the shielded system modules offered by Biologa Danell. When installing, please ensure that the mains cable is at least 80 mm straight at the plug and socket. Up to ten system modules may be plugged in one after the other without endangering the short-circuit protection. Suitable for office workstations, hi-fi systems, TV combinations ...
Shielded Modular Power System
Application:
The shielded modular system is a flexible, customisable solution for power distribution in residential, office and professional environments. Its individual components, such as power outlets, switches, connection modules and supply cables, can be combined, expanded and adapted to meet specific requirements. It is particularly well suited to workstations, technical installations, home offices, media setups and demanding living spaces, where organisation and low-EMF performance are important.
Benefits:
Thanks to continuous shielding of all system components, the modular design supports a consistent low-EMF power distribution concept, reducing low-frequency electric fields throughout the installation. The modular design also offers maximum flexibility for planning, expansion and future modifications. Additional components can be integrated quickly and easily, enabling the system to adapt to changing requirements. The result is an effective, future-proof solution that combines functionality, flexibility and EMF reduction — ideal for healthy homes, professional workplaces and building biology projects.